All Products
Overview of the chemicals, plant equipment, membranes, valves and spares we supply.
Chemicals, equipment and spares we supply
Industrial water treatment products, chemicals, replacement components and spares. Product pages describe what is supplied; service pages describe plant engineering, installation, commissioning and maintenance.
ACL CHEMICALS — Industrial Water Treatment Chemicals
ACL BOILER CHEMICALS
- Oxygen scavengers
- pH boosters / alkalinity control
- Antiscalants & dispersants
- Fireside chemicals & antifoams
- Corrosion inhibitors
- Boiler descaling chemicals & passivators
ACL COOLING TOWER CHEMICALS
- Scale & corrosion inhibitors
- Oxidising & non-oxidising biocides
- ACL ALGAECIDES & bio-dispersants
- Oil dispersants & bio-detergents
ACL ETP / STP WASTEWATER CHEMICALS
- Polyelectrolytes (cationic & anionic)
- Coagulants (alum, PAC, lime)
- ACL DEFOAMERS & water decolouring agents
- Bacterial cultures & bio-nutrients
- Odor control formulations
ACL RO MEMBRANE CHEMICALS
- RO antiscalants (high silica/high pH)
- Low pH & high pH CIP membrane cleaners
- Dechlorination agents (Sodium Metabisulphite)
- Biocides & sanitizers
- Acidic & alkaline descalants
Plant equipment, membranes & spares
RO & Softener Spares
- RO membranes (4040, 8040 industrial)
- High pressure vertical multistage pumps
- FRP pressure vessels & multiport valves
- Cation & anion exchange resins
- Rotameters & digital pressure gauges
- 1, 5, 10, 20 & 50-micron cartridge filters
- Chemical dosing pumps
Wastewater & Cooling Tower Spares
- Fine & coarse bubble diffusers
- Tube settler media & filter press spares
- Cooling tower PVC fills, fins & nozzles
- Corrosion test coupons
- Air blowers & industrial agitators
Testing kits, meters and valves
Water Testing Kits & Sensors
- Hardness, calcium, alkalinity, pH, chloride test kits
- Dissolved oxygen, hydrazine, sulphite test kits
- Phosphate, iron, zinc, chromate & silica kits
- Online & handheld pH, TDS, ORP, EC & Turbidity meters
Valves & Fittings
- Wafer & lug butterfly valves
- Two-piece & three-piece SS304/SS316 ball valves
- Bolted bonnet gate and globe valves
- IBR certified valves & steam traps
- Y-type, T-type and duplex strainers
Product parts gallery
Clear product images with the part name
Each catalog item is shown with its product name and a clear representative image. Materials, dimensions, pressure class and compatibility are confirmed against the application before supply.
Plant Spares
Ask for complete plant spares list

High-Pressure Pump
Request specification
Cartridge Filter
Request specification
Chemical Dosing Pump
Request specification
Pressure Gauge
Request specification
Control Panel
Request specification
Ion-Exchange Resin
Request specification
Rotameter
Request specification
Bubble Diffuser
Request specification
Filter Press
Request specification
Bag Filter
Request specification
Tube Settler Media
Request specification
Cooling-Tower Fill
Request specification
Filter Media
Request specification
Corrosion Coupon
Request specification
Seals / Gaskets
Request specificationIBR Valves
Ask for complete ibr valves list
Ball Valve
Request specification
Butterfly Valve
Request specification
Globe Valve
Request specification
Gate Valve
Request specification
Diaphragm Valve
Request specificationStrainers
Ask for complete strainers list
Y-Type / Line Strainer
Request specification
Duplex / Basket Strainer
Request specification
Process Strainer Element
Request specificationTesting Kits
Ask for complete testing kits list
Water Testing Kit
Request specification
Hardness / Alkalinity Test Kit
Request specification
Chloride / Sulphite / Phosphate Test Kit
Request specificationSensors & Meters
Ask for complete sensors & meters list
Conductivity / EC Meter
Request specification
pH Meter
Request specification
TDS Meter
Request specification
Flow / Rotameter Instrument
Request specificationBoiler Spares
Ask for complete boiler spares list
Burner / Burner Components
Request specification
Boiler Coil / Heat-Transfer Component
Request specification
Gaskets / Sealing Components
Request specification
Boiler Valves / Fittings
Request specification
Boiler Gauges / Level Components
Request specification
Refractory / Furnace Components
Request specificationChemical quick reference
Composition, functions, uses and directions of use for every chemical listed below
These are typical formulation families and operating directions for selection guidance. Final grade, concentration, compatibility and dosage must be established from actual water analysis, plant operating data, jar/pilot testing where relevant, and the applicable OEM / chemical supplier instructions.
| Chemical | Typical composition / active chemistry | Function | Typical uses | Directions of use |
|---|---|---|---|---|
| Boiler ACL PH BOOSTER | Sodium hydroxide, sodium carbonate or an approved alkaline blend | Raises alkalinity and supports corrosion control | Boiler-water pH/alkalinity control | Meter through a controlled dosing point; adjust from boiler-water test results and the boiler-treatment target. |
| Boiler ACL SLUDGE CONDITIONER | Phosphate/polymer dispersant formulation | Keeps precipitated hardness and iron as soft, non-adherent sludge | Internal boiler-water treatment with controlled blowdown | Dose to the feed/chemical point and tune from phosphate/alkalinity, blowdown and observed sludge condition. |
| Boiler Antiscalant / Dispersant | Phosphonate/polymer dispersant blend | Controls scale-forming deposits and disperses suspended solids | Boiler feed and internal treatment programs where specified | Dose continuously or intermittently according to feed chemistry, boiler pressure and the approved treatment program. |
| Boiler Oxygen Scavenger | Sulfite/bisulfite, DEHA or other approved scavenger chemistry | Reduces dissolved oxygen and pitting corrosion | Feedwater, deaerator and condensate protection | Dose to the required residual at the sampling point; verify by routine residual testing. |
| ACL FIRESIDE CHEMICALS | Fuel/additive blend selected for ash/soot conditioning | Conditions deposits and supports cleaner heat-transfer surfaces | Solid/liquid/gas-fuel boiler fireside treatment where applicable | Apply only to the approved fuel system and combustion conditions; follow supplier and boiler/OEM instructions. |
| Boiler Antifoam | Silicone, polyether or non-silicone antifoam formulation | Suppresses foam and reduces carry-over/priming risk | Boiler-water foaming control | Dose at the designated injection point only as required by foam observations and boiler-water testing. |
| Boiler / Condensate Corrosion Inhibitor | Filming amine, neutralizing amine or approved inhibitor blend | Protects boiler/condensate-line metal from corrosion | Condensate and steam/return-water systems | Dose from condensate pH/iron trends and supplier target; confirm compatibility with steam use. |
| Boiler Descaling Chemical | Citric, sulfamic, phosphoric or other compatible formulated acid | Dissolves existing scale and rust deposits | Shutdown cleaning of boilers and heat-transfer surfaces | Use only during controlled cleaning; prepare the OEM-approved concentration, circulate/soak, then neutralize and rinse. |
| Metal Passivator / Neutralizer | Alkaline neutralizer with corrosion-passivation additives | Neutralizes residual cleaner and reduces flash rust after cleaning | Post-descaling passivation | Use after descaling according to the cleaning procedure, temperature and specified contact time. |
| Cooling-Tower Corrosion Inhibitor | Phosphate/phosphonate/zinc or alloy-specific inhibitor program | Forms protective films and reduces corrosion | Open recirculating cooling-water systems | Dose to the program residual target and monitor pH, conductivity and corrosion indicators. |
| Cooling-Tower ACL SCALE INHIBITOR | Phosphonate/polymer antiscalant blend | Controls carbonate, sulfate and selected silica scale | Cooling circuits and heat exchangers | Dose continuously or intermittently based on cycles of concentration and current make-up-water chemistry. |
| Cooling-Tower Oxidizing Biocide | ACL HYPOCHLORITE, bromine or other approved oxidizing biocide | Controls bacteria and biofilm-forming organisms | Cooling towers and recirculating systems | Apply only to the approved shock/continuous program and verify the required residual. |
| Cooling-Tower Non-Oxidizing Biocide | Isothiazolinone, DBNPA or other approved non-oxidizing chemistry | Controls microbial growth without relying on an oxidizing mechanism | Cooling-water microbiological control | Dose as a scheduled treatment/shock with system volume and active concentration verified by the treatment program. |
| Algaecide | Quaternary ammonium, copper-based or other approved algaecide | Controls algae growth on wet/open surfaces | Cooling basins, fills and water-distribution areas | Use the approved treatment concentration and exposure time; correct nutrient/light causes where possible. |
| Bio-Dispersant | Polymer/surfactant dispersant blend | Loosens slime and biofilm so biocides can work effectively | Cooling-water biofilm control | Introduce ahead of or with the approved biocide program and monitor suspended solids/blowdown. |
| Oil Dispersant | Surfactant/dispersant formulation | Disperses oil and grease contamination | Cooling towers affected by process leakage | Use only after source control and according to compatibility checks for the cooling system. |
| Bio Detergent | Surfactant/enzymatic or formulated biological cleaner | Removes organic and biological deposits | Cooling-system cleaning and housekeeping | Apply during an approved cleaning cycle and flush according to the procedure. |
| ETP/STP Polyelectrolyte | Cationic or anionic polyacrylamide-type polymer | Bridges particles into larger flocs and improves settling/dewatering | Clarifiers, DAF and sludge-dewatering equipment | Prepare make-down solution as supplied, then optimize dose by jar testing or dewatering trials. |
| ETP/STP Coagulant (PAC/Alum/Lime) | Poly aluminium chloride, alum or lime depending on duty | Destabilizes colloids and supports precipitation/clarification | TSS, colour, phosphorus and metals treatment as applicable | Run a jar test to determine the lowest effective dose and monitor pH before/after dosing. |
| ACL WATER DECOLORING Agent | Cationic polymer/coagulant/decolorant blend | Removes dissolved/colloidal colour bodies | Textile, paper, dye and coloured industrial effluent | Dose from jar testing; optimize against colour, COD/TSS and sludge production. |
| ETP/STP Defoamer | Silicone, polyether or non-silicone antifoam | Reduces foam and surface carry-over | Aeration, equalization and outlet tanks | Apply only as needed and avoid overdosing, which can interfere with downstream biology. |
| ACL LIME / ALUM | Calcium hydroxide and aluminium sulfate formulations | Neutralization, precipitation and coagulation | Wastewater pH adjustment and primary clarification | Add through controlled dosing; determine the dose by jar test and required final pH. |
| ACL BIO CULTURES / Bio-Nutrients | Selected microbial consortium plus nutrients where required | Supports biological treatment start-up and biomass activity | ETP/STP biological reactors | Add to the biological stage only after confirming process conditions, oxygen availability and nutrient balance. |
| RO Antiscalant | Phosphonate/polyacrylate/polymer dispersant blend | Controls carbonate, sulfate, silica and metal scaling on membranes | RO feed-water treatment | Dose from current water analysis and RO projection; verify permeate performance and membrane feed conditions. |
| RO Low-pH Cleaner | Citric/other organic acids or formulated acidic cleaner | Removes inorganic scale and metal deposits | RO membrane CIP for confirmed inorganic fouling | Prepare within the membrane manufacturer's approved pH/concentration and circulate/soak as specified. |
| RO High-pH Cleaner | NaOH-based alkaline blend with surfactants/chelants as applicable | Removes organic, colloidal and biological fouling | RO/UF membrane CIP | Prepare within OEM-approved pH/concentration and control temperature, circulation and soak time. |
| RO CIP Chemical Program | Compatible acidic + alkaline cleaner sequence selected for foulant | Restores membrane flux and salt rejection | Planned RO clean-in-place maintenance | Select the sequence from foulant diagnosis; isolate, flush, circulate, soak and rinse per membrane/OEM procedure. |
| Chlorine Inhibitor / Dechlorination Agent | Sodium metabisulfite (SMBS) or other approved reducing agent | Removes residual chlorine and protects polyamide membranes | RO feed dechlorination | Dose upstream and verify chlorine residual at the RO inlet rather than relying on a fixed dose. |
| Chlorinating Agent | Sodium hypochlorite, calcium hypochlorite or other approved disinfectant | Disinfects raw water and pretreatment sections | Raw-water tank, media filters and sanitization where membrane compatibility permits | Apply only upstream of chlorine-sensitive membranes and remove residual chlorine before the RO membrane stage. |
| UF Cleaning Chemical | Acidic/alkaline/surfactant cleaner selected for UF foulant | Restores UF permeability and reduces fouling | UF membrane cleaning | Choose cleaner from foulant diagnosis and use the membrane/OEM concentration, pH and temperature limits. |
| ACL HYDROCHLORIC ACID (HCl) | Hydrochloric acid in approved commercial concentration | Lowers pH and dissolves carbonate scale | RO pretreatment, ion-exchange regeneration and compatible CIP duties | Dose through a corrosion-compatible system with controlled pH feedback; always follow site acid-handling procedures. |
| Caustic Soda (NaOH) | Sodium hydroxide | Raises pH and provides alkaline cleaning/regeneration | RO/UF alkaline cleaning, ETP neutralization and anion-resin regeneration | Meter into a controlled system and adjust to the process setpoint or OEM cleaning target. |
| ACL HYPOCHLORITE | Sodium hypochlorite or calcium hypochlorite | Oxidizing disinfectant for microbiological control | Raw water, storage tanks and pretreatment sanitization | Dose to the approved free-chlorine target and always verify residual before chlorine-sensitive RO membranes. |
| Sodium Metabisulfite (SMBS) | Na₂S₂O₅ | Dechlorinates RO feed and can preserve membranes during storage | RO dechlorination and membrane preservation | Prepare a fresh solution when required, dose to chlorine-demand, and verify residual at the membrane inlet. |
Important: do not apply a universal dose directly to another plant. Confirm chemical strength, compatibility, PPE, ventilation, storage, injection point, membrane/boiler/OEM limits and the site's approved chemical-handling procedure before use.
How our chemicals work
Water treatment chemicals and their functions
Every chemical programme is selected for the plant it protects. See what each of our boiler, cooling tower, ETP / STP and RO chemicals does.

ACL BOILER CHEMICALS
Protect boiler tubes, drums and condensate lines from scale, corrosion and carry-over while improving fuel efficiency.
ACL PH BOOSTER
Raises and holds boiler water alkalinity in the correct range so steel surfaces stay passive and acidic corrosion is prevented.
ACL SLUDGE CONDITIONER
Keeps hardness salts and iron as soft, non-sticky sludge that stays suspended and leaves with blowdown instead of baking onto tubes.
ACL ANTI-SCALANTS
Sequester calcium, magnesium and silica to stop hard scale forming on heating surfaces, keeping heat transfer high and fuel use low.
ACL OXYGEN SCAVENGERS
Remove dissolved oxygen from feed water to prevent pitting corrosion in the boiler, economiser and feed lines.
ACL FIRESIDE CHEMICALS
Condition soot, slag and clinker on the fire side, improving combustion and keeping flue passages and tubes clean.
ACL ANTIFOAMS
Break foam in boiler water to prevent priming and carry-over of water and dissolved solids into the steam.
ACL CORROSION INHIBITORS
Form a protective film on boiler and condensate-line metal to prevent corrosion caused by oxygen and carbon dioxide.
ACL DESCALING CHEMICALS
Dissolve existing scale and rust deposits during shutdown cleaning, restoring heat transfer and extending tube life.
ACL METAL PASSIVATOR / NEUTRALIZERS
Neutralise residual acid after descaling and rebuild a passive oxide layer so freshly cleaned metal does not flash-rust.

ACL COOLING TOWER CHEMICALS
Keep heat exchangers, condensers and fills clean and corrosion-free so the cooling circuit delivers design approach temperature.
ACL CORROSION INHIBITORS
Phosphate, zinc and alloy-based programmes form a protective film on mild steel, copper and alloy surfaces of exchangers and pipelines.
ACL SCALE INHIBITOR
Keeps calcium carbonate, sulphate and silica in solution at higher cycles of concentration, preventing scale and saving make-up water.
Biocides (oxidizing & non-oxidizing)
Kill bacteria, fungi and Legionella in recirculating water; alternating both types prevents microbial resistance.
ACL ALGAECIDES
Control algae on basins, decks, distribution channels and fills exposed to sunlight, preventing blockage and fouling.
Bio Dispersants (foaming & non-foaming)
Loosen and lift biofilm and slime so biocides penetrate better and debris is flushed out with blowdown.
ACL OIL DISPERSANTS
Emulsify oil and grease leaking in from the process so they do not coat heat-exchanger surfaces or foul fill media.
ACL BIO DETERGENTS
Clean organic and biological fouling from system surfaces during online or offline cleaning to restore heat-transfer efficiency.


ACL ETP / STP WASTEWATER CHEMICALS
Help effluent and sewage treatment plants meet discharge norms for COD, BOD, TSS, colour and odour, and handle sludge efficiently.
ACL POLY ELECTROLYTES
Cationic and anionic polymers bridge fine particles into large, fast-settling flocs in clarifiers, improving TSS and COD removal.
ACL SLUDGE DEWATERING
Conditions sludge before the filter press, belt press or centrifuge so water separates easily and a drier cake is produced.
ACL WATER DECOLORING
Removes dye and colour from textile, paper, pharma and distillery effluent by coagulating colour molecules for separation.
ACL DEFOAMERS
Knock down foam in aeration, equalisation and outlet tanks, preventing overflow and improving oxygen transfer.
ACL LIME / ALUM
Lime neutralises acidic effluent and precipitates heavy metals; alum coagulates suspended solids and phosphate in primary treatment.
ACL BIO CULTURES
Specialised bacteria and nutrients seed and boost biological treatment, speeding start-up, improving BOD/COD reduction and controlling odour.

RO Water Treatment Chemicals
Protect RO and UF membranes from scaling, fouling and chlorine damage so the plant keeps its output, recovery and salt rejection.
ACL RO ANTISCALANTS
High/low silica and high/low pH grades prevent carbonate, sulphate, silica and metal scale on membranes, allowing higher recovery.
ACL LOW PH CLEANERS
Acidic cleaners dissolve inorganic scale and metal oxides such as calcium carbonate and iron from the membrane surface.
ACL HIGH PH CLEANERS
Alkaline cleaners remove organic fouling, biofilm and colloidal silt that reduce permeate flow.
ACL C.I.P CHEMICALS
Complete clean-in-place programmes restore flux and salt rejection without dismantling membranes from the pressure vessels.
ACL CHLORINE INHIBITORS
Neutralise residual chlorine in RO feed water to protect polyamide membranes from irreversible oxidation damage.
ACL CHLORINATING AGENTS
Disinfect raw water and pre-treatment to control bacterial growth before filtration and membranes.
ACL ULTRA FILTRATION CLEANING CHEMICALS
Clean UF membranes of organics, biofouling and particulates to recover permeability and backwash efficiency.
ACL HYDROCHLORIC ACID (HCl)
Lowers feed pH to limit carbonate scaling and is used for acid cleaning and cation resin regeneration.
ACL CAUSTIC (NaOH)
Raises pH for alkaline membrane cleaning and silica control, and regenerates anion exchange resin.
ACL HYPOCHLORITE
Oxidising disinfectant for raw water, storage tanks and pre-treatment sanitisation.
ACL SODIUM META BI-SULPHITE
Dechlorinates RO feed water and preserves membranes during storage or plant shutdown.
Full lists by category

Chemicals
Boiler, cooling tower, wastewater and RO treatment chemicals.

Plant Spares
Spares for cooling towers, wastewater, RO and softener plants.

IBR Valves
Ball, butterfly, globe, gate and diaphragm valves.

Strainers & Kits
Strainers, water testing kits, sensors and meters.

Boiler Spares
Boiler key parts, major parts and other spare parts.